Error CodeBrandMeaning of Error CodePotential Solution
SESamsungShort circuit or sensor error detected in the control systemUnplug microwave for 5 minutes to reset. If error persists, contact technician to check sensors and wiring
E-11SamsungCommunication error between control board and touchpadCheck touchpad connection. Reset by unplugging for 10 minutes. May require control board replacement
E-13SamsungHumidity sensor malfunction or failureClean interior thoroughly. If error continues, humidity sensor needs replacement by technician
E-41SamsungTemperature sensor error – unable to read correct temperatureAllow microwave to cool down completely. Check sensor connections. Replace temperature sensor if faulty
C-10SamsungGas sensor error (in combination models)Ventilate area. Reset microwave. Contact service if error persists as gas sensor may be damaged
C-20SamsungAbnormal high temperature detectedStop operation immediately. Allow to cool for 30+ minutes. Check ventilation. Call technician if repeats
C-21SamsungOverheating protection activatedEnsure proper ventilation around unit. Clean air vents. Allow cooling period before restarting
F1LGTemperature sensor failureCheck sensor wire connections. Replace faulty temperature sensor. Reset by unplugging for 10 minutes
F2LGDoor switch malfunction or door not closing properlyInspect door alignment and latch mechanism. Clean door seals. Replace faulty door switch
F3LGTouchpad or control panel errorClean touchpad with dry cloth. Check for moisture. Reset unit. Replace control panel if necessary
F4LGHumidity sensor errorClean sensor area inside cavity. Reset microwave. Replace sensor if problem continues
F5LGCooling fan motor failureCheck for obstructions in fan area. Listen for unusual noises. Replace cooling fan motor if not functioning
F6LGHigh voltage transformer issueDangerous error – do not attempt DIY repair. Contact authorized technician immediately
F7LGMagnetron failure (no heating)Check power supply. If magnetron failed, requires professional replacement. Do not operate
E-11WhirlpoolTouchpad/control panel communication errorDisconnect power for 5 minutes. Check ribbon cable connections. Replace control board if needed
E-21WhirlpoolDoor latch/interlock switch problemInspect door mechanism for damage. Clean latch area. Replace door switches if faulty
E-24WhirlpoolHumidity sensor malfunctionClean sensor. Reset microwave. Contact service for sensor replacement if error persists
E-41WhirlpoolThermal cutout activated due to overheatingAllow microwave to cool completely. Check ventilation. Clean air vents. Reset thermal cutout
F1E1WhirlpoolMain control board failureReset by unplugging. If error returns, main control board needs professional replacement
F3E2WhirlpoolOven temperature sensor open circuitCheck sensor connections and wiring. Replace temperature sensor if open or damaged
E01BoschDoor error – door not properly closed or lockedClose door firmly. Check for obstructions. Clean door seal. Adjust or replace door latch
E02BoschKey panel error or stuck buttonClean control panel. Check for stuck buttons. Reset microwave. Replace touchpad if necessary
E03BoschElectronic control malfunctionPower cycle the unit. If error repeats, electronic control board requires replacement
E04BoschTemperature sensor short circuitCheck sensor wiring for damage. Replace shorted temperature sensor
E05BoschCommunication error between componentsCheck all wire harness connections. Reset system. May require control board replacement
E10ElectroluxDoor interlock system failureTest door switches. Clean door area. Replace faulty interlock switches
E11ElectroluxControl board communication errorReset by disconnecting power. Check connections. Replace control board if defective
E15ElectroluxOverheating protection activatedAllow cooling period. Check ventilation system. Clean filters and vents thoroughly
E20ElectroluxThermal sensor faultInspect sensor and wiring. Replace temperature sensor if readings are incorrect
ER-01PanasonicDoor sensor malfunctionCheck door alignment. Clean door contacts. Replace door sensor switch if faulty
ER-02PanasonicTemperature sensor errorAllow microwave to reach room temperature. Check sensor connections. Replace if defective
ER-03PanasonicInverter circuit problemSerious electrical issue – requires professional diagnosis and repair of inverter board
ER-04PanasonicHumidity sensor failureClean sensor area. Reset unit. Contact service for humidity sensor replacement
ER-05PanasonicControl panel/membrane switch errorClean control panel. Check for moisture or stuck buttons. Replace membrane switch if needed
H-97PanasonicHigh temperature safety shut-offStop use immediately. Allow extensive cooling. Check for proper ventilation. Call service
H-98PanasonicAbnormal heating detectedDo not use. Unplug immediately. Requires professional inspection of heating components
E-11SharpMemory chip error or software malfunctionPerform hard reset by unplugging for 15 minutes. May require software update or board replacement
E-14SharpDoor sensor or interlock failureInspect door mechanism. Test door switches. Replace faulty interlock system
E-16SharpTemperature sensor open or shortedCheck sensor resistance. Replace temperature sensor if out of specification
E-41SharpHumidity sensor abnormalityClean sensor thoroughly. Reset microwave. Replace sensor if error continues
E-71SharpControl panel keypad malfunctionClean keypad area. Check for moisture or damage. Replace control panel assembly
F-1GEPrimary control board failureReset by unplugging for 10 minutes. If error returns, control board needs replacement
F-2GEKeypad/user interface errorClean control panel. Check membrane switch. Reset unit. Replace UI board if necessary
F-3GEDoor sensing circuit failureTest door switches with multimeter. Replace faulty door switch or sensor
F-4GEHumidity sensor malfunctionClean cavity and sensor. Reset microwave. Replace humidity sensor if problem persists
F-5GECooling system faultCheck cooling fan operation. Remove obstructions. Replace fan motor if not running
F-6GERelay board problemInspect relay board for burnt components. Requires professional diagnosis and replacement
F-7GEMagnetron circuit issueSerious problem – do not use. Contact authorized service for magnetron replacement
E-10SiemensGeneral system errorPerform complete reset by disconnecting power for 15 minutes. Check all connections
E-11SiemensTemperature sensing errorAllow unit to reach room temperature. Check sensor wiring. Replace sensor if faulty
E-12SiemensOverheating detectedStop operation. Allow cooling period. Clean ventilation system. Check for blocked vents
E-13SiemensDoor mechanism failureInspect door hinges and latch. Adjust door alignment. Replace door components if broken
E-14SiemensControl electronics malfunctionReset system. Check power supply. May require control module replacement
Err1ToshibaDoor circuit error – door not properly engagedClose door securely. Check door seal and alignment. Replace door switches if defective
Err2ToshibaMain control board communication failurePower cycle the microwave. Check wire harnesses. Replace control board if needed
Err3ToshibaTemperature probe errorCheck probe connection and condition. Replace temperature probe if damaged or open
Err4ToshibaHumidity sensor abnormalityClean sensor location. Reset microwave. Service required if sensor is faulty
Err5ToshibaCooling fan motor failureListen for fan operation. Remove obstructions. Replace fan motor if not functioning
E1KenmoreTouchpad short circuit or stuck buttonClean touchpad thoroughly. Check for moisture. Reset by unplugging. Replace if necessary
E2KenmoreDoor switch or interlock failureTest all door switches. Clean door contacts. Replace faulty door interlock switches
E3KenmoreControl board malfunctionDisconnect power for reset. Check for loose connections. Replace control board if defective
E4KenmoreThermal sensor errorCheck sensor wiring and connections. Replace temperature sensor if readings are incorrect
E5KenmoreHumidity sensor problemClean sensor area inside cavity. Reset unit. Replace sensor if error continues
PFVarious BrandsPower failure – temporary power interruption occurredSimply press STOP/CLEAR or CANCEL button and reset clock. No repair needed
LOCKEDVarious BrandsControl lock feature is activatedPress and hold STOP/CLEAR button for 3-5 seconds to unlock control panel
DEMOVarious BrandsDemonstration mode is activatedConsult manual for specific deactivation sequence (usually press specific button combinations)
dOOrVarious BrandsDoor is not closed or door switch problemClose door firmly. Check for obstructions. Clean door seal. Replace door switch if faulty
E-41MieleTemperature sensor short circuit or openCheck sensor resistance with multimeter. Replace sensor if out of acceptable range
F-01MieleElectronic module defectReset by turning off circuit breaker for 5 minutes. Contact service for module replacement
F-11MieleDoor lock errorCheck door mechanism. Clean door area. Replace door lock assembly if malfunctioning
F-40MieleCommunication error with displayCheck ribbon cable connections. Reset system. May require display module replacement
ErrHaierGeneral system error – multiple possible causesUnplug for 10 minutes. Check for loose connections. Contact service if error persists
E-01HaierDoor circuit problemInspect door switches and wiring. Clean contacts. Replace faulty door switch
E-02HaierControl panel communication failureClean control panel. Reset microwave. Check wire connections. Replace if necessary
E-03HaierTemperature sensor abnormalityAllow cooling to room temperature. Test sensor. Replace if defective
E1BruhmDoor error – not closing properlyEnsure door closes completely. Check alignment. Replace door latch if damaged
E2BruhmSensor error (temperature or humidity)Clean sensor areas. Reset by unplugging. Replace sensor if error continues
E3BruhmControl system malfunctionPerform power reset. Check connections. May require control board replacement
F0RamtonsSystem initialization errorUnplug microwave for 15 minutes. Plug back in to reset initialization. Contact service if repeats
F1RamtonsTemperature sensing failureCheck sensor connection and condition. Replace temperature sensor if faulty
F2RamtonsDoor interlock errorTest door switches. Adjust door alignment. Replace interlock switches if not working
F3RamtonsControl panel/keypad errorClean control panel. Check for stuck buttons. Reset unit. Replace panel if necessary

Important Safety Notes

Warning: Many microwave oven errors involve high-voltage components that can store dangerous electrical charges even when unplugged. Never attempt to repair internal components yourself unless you are a qualified technician. Microwaves contain capacitors that can deliver fatal shocks.

When to Call a Professional:

  • Any error involving the magnetron, high-voltage transformer, or capacitor
  • Persistent errors after basic troubleshooting
  • Burning smells or sparking inside the unit
  • Physical damage to internal components
  • Multiple error codes appearing simultaneously

Basic Troubleshooting Steps:

  1. Unplug the microwave and wait 5-10 minutes
  2. Check power supply and circuit breaker
  3. Inspect door alignment and cleanliness
  4. Clean ventilation areas and filters
  5. Plug back in and test

Contact Information for Professional Service: If error codes persist after basic troubleshooting, contact a qualified appliance repair service specializing in microwave ovens. Always provide the exact error code, brand, and model number when calling for service.