Comprehensive Microwave Oven Error Codes Table

Comprehensive Microwave Oven Error Codes Table

Error Code Brand Meaning of Error Code Potential Solution
SE Samsung Short circuit or sensor error detected in the control system Unplug microwave for 5 minutes to reset. If error persists, contact technician to check sensors and wiring
E-11 Samsung Communication error between control board and touchpad Check touchpad connection. Reset by unplugging for 10 minutes. May require control board replacement
E-13 Samsung Humidity sensor malfunction or failure Clean interior thoroughly. If error continues, humidity sensor needs replacement by technician
E-41 Samsung Temperature sensor error – unable to read correct temperature Allow microwave to cool down completely. Check sensor connections. Replace temperature sensor if faulty
C-10 Samsung Gas sensor error (in combination models) Ventilate area. Reset microwave. Contact service if error persists as gas sensor may be damaged
C-20 Samsung Abnormal high temperature detected Stop operation immediately. Allow to cool for 30+ minutes. Check ventilation. Call technician if repeats
C-21 Samsung Overheating protection activated Ensure proper ventilation around unit. Clean air vents. Allow cooling period before restarting
F1 LG Temperature sensor failure Check sensor wire connections. Replace faulty temperature sensor. Reset by unplugging for 10 minutes
F2 LG Door switch malfunction or door not closing properly Inspect door alignment and latch mechanism. Clean door seals. Replace faulty door switch
F3 LG Touchpad or control panel error Clean touchpad with dry cloth. Check for moisture. Reset unit. Replace control panel if necessary
F4 LG Humidity sensor error Clean sensor area inside cavity. Reset microwave. Replace sensor if problem continues
F5 LG Cooling fan motor failure Check for obstructions in fan area. Listen for unusual noises. Replace cooling fan motor if not functioning
F6 LG High voltage transformer issue Dangerous error – do not attempt DIY repair. Contact authorized technician immediately
F7 LG Magnetron failure (no heating) Check power supply. If magnetron failed, requires professional replacement. Do not operate
E-11 Whirlpool Touchpad/control panel communication error Disconnect power for 5 minutes. Check ribbon cable connections. Replace control board if needed
E-21 Whirlpool Door latch/interlock switch problem Inspect door mechanism for damage. Clean latch area. Replace door switches if faulty
E-24 Whirlpool Humidity sensor malfunction Clean sensor. Reset microwave. Contact service for sensor replacement if error persists
E-41 Whirlpool Thermal cutout activated due to overheating Allow microwave to cool completely. Check ventilation. Clean air vents. Reset thermal cutout
F1E1 Whirlpool Main control board failure Reset by unplugging. If error returns, main control board needs professional replacement
F3E2 Whirlpool Oven temperature sensor open circuit Check sensor connections and wiring. Replace temperature sensor if open or damaged
E01 Bosch Door error – door not properly closed or locked Close door firmly. Check for obstructions. Clean door seal. Adjust or replace door latch
E02 Bosch Key panel error or stuck button Clean control panel. Check for stuck buttons. Reset microwave. Replace touchpad if necessary
E03 Bosch Electronic control malfunction Power cycle the unit. If error repeats, electronic control board requires replacement
E04 Bosch Temperature sensor short circuit Check sensor wiring for damage. Replace shorted temperature sensor
E05 Bosch Communication error between components Check all wire harness connections. Reset system. May require control board replacement
E10 Electrolux Door interlock system failure Test door switches. Clean door area. Replace faulty interlock switches
E11 Electrolux Control board communication error Reset by disconnecting power. Check connections. Replace control board if defective
E15 Electrolux Overheating protection activated Allow cooling period. Check ventilation system. Clean filters and vents thoroughly
E20 Electrolux Thermal sensor fault Inspect sensor and wiring. Replace temperature sensor if readings are incorrect
ER-01 Panasonic Door sensor malfunction Check door alignment. Clean door contacts. Replace door sensor switch if faulty
ER-02 Panasonic Temperature sensor error Allow microwave to reach room temperature. Check sensor connections. Replace if defective
ER-03 Panasonic Inverter circuit problem Serious electrical issue – requires professional diagnosis and repair of inverter board
ER-04 Panasonic Humidity sensor failure Clean sensor area. Reset unit. Contact service for humidity sensor replacement
ER-05 Panasonic Control panel/membrane switch error Clean control panel. Check for moisture or stuck buttons. Replace membrane switch if needed
H-97 Panasonic High temperature safety shut-off Stop use immediately. Allow extensive cooling. Check for proper ventilation. Call service
H-98 Panasonic Abnormal heating detected Do not use. Unplug immediately. Requires professional inspection of heating components
E-11 Sharp Memory chip error or software malfunction Perform hard reset by unplugging for 15 minutes. May require software update or board replacement
E-14 Sharp Door sensor or interlock failure Inspect door mechanism. Test door switches. Replace faulty interlock system
E-16 Sharp Temperature sensor open or shorted Check sensor resistance. Replace temperature sensor if out of specification
E-41 Sharp Humidity sensor abnormality Clean sensor thoroughly. Reset microwave. Replace sensor if error continues
E-71 Sharp Control panel keypad malfunction Clean keypad area. Check for moisture or damage. Replace control panel assembly
F-1 GE Primary control board failure Reset by unplugging for 10 minutes. If error returns, control board needs replacement
F-2 GE Keypad/user interface error Clean control panel. Check membrane switch. Reset unit. Replace UI board if necessary
F-3 GE Door sensing circuit failure Test door switches with multimeter. Replace faulty door switch or sensor
F-4 GE Humidity sensor malfunction Clean cavity and sensor. Reset microwave. Replace humidity sensor if problem persists
F-5 GE Cooling system fault Check cooling fan operation. Remove obstructions. Replace fan motor if not running
F-6 GE Relay board problem Inspect relay board for burnt components. Requires professional diagnosis and replacement
F-7 GE Magnetron circuit issue Serious problem – do not use. Contact authorized service for magnetron replacement
E-10 Siemens General system error Perform complete reset by disconnecting power for 15 minutes. Check all connections
E-11 Siemens Temperature sensing error Allow unit to reach room temperature. Check sensor wiring. Replace sensor if faulty
E-12 Siemens Overheating detected Stop operation. Allow cooling period. Clean ventilation system. Check for blocked vents
E-13 Siemens Door mechanism failure Inspect door hinges and latch. Adjust door alignment. Replace door components if broken
E-14 Siemens Control electronics malfunction Reset system. Check power supply. May require control module replacement
Err1 Toshiba Door circuit error – door not properly engaged Close door securely. Check door seal and alignment. Replace door switches if defective
Err2 Toshiba Main control board communication failure Power cycle the microwave. Check wire harnesses. Replace control board if needed
Err3 Toshiba Temperature probe error Check probe connection and condition. Replace temperature probe if damaged or open
Err4 Toshiba Humidity sensor abnormality Clean sensor location. Reset microwave. Service required if sensor is faulty
Err5 Toshiba Cooling fan motor failure Listen for fan operation. Remove obstructions. Replace fan motor if not functioning
E1 Kenmore Touchpad short circuit or stuck button Clean touchpad thoroughly. Check for moisture. Reset by unplugging. Replace if necessary
E2 Kenmore Door switch or interlock failure Test all door switches. Clean door contacts. Replace faulty door interlock switches
E3 Kenmore Control board malfunction Disconnect power for reset. Check for loose connections. Replace control board if defective
E4 Kenmore Thermal sensor error Check sensor wiring and connections. Replace temperature sensor if readings are incorrect
E5 Kenmore Humidity sensor problem Clean sensor area inside cavity. Reset unit. Replace sensor if error continues
PF Various Brands Power failure – temporary power interruption occurred Simply press STOP/CLEAR or CANCEL button and reset clock. No repair needed
LOCKED Various Brands Control lock feature is activated Press and hold STOP/CLEAR button for 3-5 seconds to unlock control panel
DEMO Various Brands Demonstration mode is activated Consult manual for specific deactivation sequence (usually press specific button combinations)
dOOr Various Brands Door is not closed or door switch problem Close door firmly. Check for obstructions. Clean door seal. Replace door switch if faulty
E-41 Miele Temperature sensor short circuit or open Check sensor resistance with multimeter. Replace sensor if out of acceptable range
F-01 Miele Electronic module defect Reset by turning off circuit breaker for 5 minutes. Contact service for module replacement
F-11 Miele Door lock error Check door mechanism. Clean door area. Replace door lock assembly if malfunctioning
F-40 Miele Communication error with display Check ribbon cable connections. Reset system. May require display module replacement
Err Haier General system error – multiple possible causes Unplug for 10 minutes. Check for loose connections. Contact service if error persists
E-01 Haier Door circuit problem Inspect door switches and wiring. Clean contacts. Replace faulty door switch
E-02 Haier Control panel communication failure Clean control panel. Reset microwave. Check wire connections. Replace if necessary
E-03 Haier Temperature sensor abnormality Allow cooling to room temperature. Test sensor. Replace if defective
E1 Bruhm Door error – not closing properly Ensure door closes completely. Check alignment. Replace door latch if damaged
E2 Bruhm Sensor error (temperature or humidity) Clean sensor areas. Reset by unplugging. Replace sensor if error continues
E3 Bruhm Control system malfunction Perform power reset. Check connections. May require control board replacement
F0 Ramtons System initialization error Unplug microwave for 15 minutes. Plug back in to reset initialization. Contact service if repeats
F1 Ramtons Temperature sensing failure Check sensor connection and condition. Replace temperature sensor if faulty
F2 Ramtons Door interlock error Test door switches. Adjust door alignment. Replace interlock switches if not working
F3 Ramtons Control panel/keypad error Clean control panel. Check for stuck buttons. Reset unit. Replace panel if necessary

Important Safety Notes

Warning: Many microwave oven errors involve high-voltage components that can store dangerous electrical charges even when unplugged. Never attempt to repair internal components yourself unless you are a qualified technician. Microwaves contain capacitors that can deliver fatal shocks.

When to Call a Professional:

  • Any error involving the magnetron, high-voltage transformer, or capacitor
  • Persistent errors after basic troubleshooting
  • Burning smells or sparking inside the unit
  • Physical damage to internal components
  • Multiple error codes appearing simultaneously

Basic Troubleshooting Steps:

  1. Unplug the microwave and wait 5-10 minutes
  2. Check power supply and circuit breaker
  3. Inspect door alignment and cleanliness
  4. Clean ventilation areas and filters
  5. Plug back in and test

Contact Information for Professional Service: If error codes persist after basic troubleshooting, contact a qualified appliance repair service specializing in microwave ovens. Always provide the exact error code, brand, and model number when calling for service.

RELATED